Skip to content

Guide

Peptide reconstitution chart: concentration and U-100 units

A chart of concentration and syringe units for common vial sizes and water volumes, on a U-100 insulin syringe. Arithmetic only, not dose advice.

Three relationships carry this whole page. Concentration in mg/mL = mg of peptide in the vial ÷ mL of water added. On a U-100 insulin syringe, 1 unit = 0.01 mL, so 100 units = 1 mL. And what one unit holds follows from the first two: mcg per unit = concentration in mg/mL × 10.

This page is arithmetic and nothing else. It shows what happens to a concentration when the vial size or the water volume changes. It does not tell you how much of anything to take, and no figure on it is a recommended amount.

How the water volume changes the concentration

The amount of peptide in a vial is fixed by what was put in it. Adding water does not add or remove any peptide — it only decides how far that fixed amount is spread out.

So the relationships run one way. Double the water and the concentration halves. Halve the concentration and each unit mark on the syringe holds half as much. Which means the same quantity of peptide occupies twice as many marks, and that is the whole trade-off: more water spreads the vial across more of the syringe, less water packs it into fewer.

Nothing in that is a judgement about which is better. It is the reason the chart below has two axes instead of one.

Chart A: concentration by vial size and water volume

Each cell gives the concentration in mg/mL, then how much peptide one unit on a U-100 syringe holds at that concentration. Figures are rounded to three significant digits.

Read across a row to see what water does: the vial stays the same and every step up in volume lowers the concentration. Read down a column to see what vial size does at a fixed volume.

Different combinations land on the same concentration — a 5 mg vial in 1 mL, a 10 mg vial in 2 mL and a 15 mg vial in 3 mL are all the same strength. Concentration is what the syringe arithmetic depends on, not the vial size by itself.

Concentration in mg/mL, and micrograms per unit on a U-100 syringe, for six vial sizes in one, two or three millilitres of water.
Vial+ 1 mL water+ 2 mL water+ 3 mL water
2 mg2 mg/mL · 20 mcg/unit1 mg/mL · 10 mcg/unit0.667 mg/mL · 6.67 mcg/unit
5 mg5 mg/mL · 50 mcg/unit2.5 mg/mL · 25 mcg/unit1.67 mg/mL · 16.7 mcg/unit
10 mg10 mg/mL · 100 mcg/unit5 mg/mL · 50 mcg/unit3.33 mg/mL · 33.3 mcg/unit
15 mg15 mg/mL · 150 mcg/unit7.5 mg/mL · 75 mcg/unit5 mg/mL · 50 mcg/unit
20 mg20 mg/mL · 200 mcg/unit10 mg/mL · 100 mcg/unit6.67 mg/mL · 66.7 mcg/unit
30 mg30 mg/mL · 300 mcg/unit15 mg/mL · 150 mcg/unit10 mg/mL · 100 mcg/unit

Chart B: syringe units and volume

The other half of the conversion is the syringe itself. Units are volume marks, and what a unit means depends on the scale the barrel was printed for.

A U-100 syringe is marked for 100 units per millilitre and a U-40 for 40, so the same number of units is two and a half times more liquid on a U-40 than on a U-100. Every chart on this page assumes U-100.

What a number of syringe units is worth in millilitres, on a U-100 and on a U-40 barrel.
Units markedVolume on a U-100 syringeVolume on a U-40 syringe
1 unit0.01 mL0.025 mL
5 units0.05 mL0.125 mL
10 units0.10 mL0.25 mL
20 units0.20 mL0.50 mL
30 units0.30 mL0.75 mL
40 units0.40 mL1.00 mL
50 units0.50 mL—
100 units1.00 mL—

Where this arithmetic goes wrong

Two of these have names the glossary defines: dead space, the liquid that stays in the needle and hub, and bacteriostatic water, the diluent itself.

  • Reading a U-40 syringe as U-100, or the reverse

    The marks are not interchangeable between scales. Reading U-40 marks as if they were U-100 moves two and a half times the intended volume; the reverse moves 40% of it. Check the scale printed on the packaging.

  • Treating units as millilitres

    On a U-100 syringe ten units is a tenth of a millilitre, not a whole one. Reading a unit as a millilitre is a hundredfold error.

  • Sliding between milligrams and micrograms

    A milligram is a thousand micrograms. Slipping between them is a thousandfold error. Chart A gives both units for every cell so that the conversion never has to happen in your head.

  • Ignoring what stays in the needle

    Some liquid remains in the needle and hub and is never delivered. With very small volumes, that leftover is a bigger share of what was drawn.

  • Working at the coarse end of the scale

    The gaps between marks on a syringe are fixed. At a high concentration a small quantity of peptide occupies only a few marks, where misreading by half a mark is a large proportion of the total. A lower concentration spreads the same quantity over more marks.

  • Adding the water in the wrong order

    The water goes into the vial of powder, not the other way round, and the concentration only holds once all of the stated water is in. Reconstitution has an order to it, and the step-by-step belongs in the reconstitution guide rather than here.

  • Trusting the number printed on the vial

    Every figure on this page assumes the vial contains what its label says. Research-chemical vials carry no manufacturing standard, so that is an assumption rather than a fact, and no amount of correct arithmetic repairs a wrong starting number.

Questions

How do I read the chart? Find your vial size down the left of Chart A and the water you added along the top. The cell gives the resulting concentration, and how much peptide each unit on a U-100 syringe holds at it.

What does micrograms per unit mean? It is how much peptide sits in the liquid between two adjacent unit marks, a hundredth of a millilitre, at that concentration. It is a property of the solution and not an amount anyone should take.

Does adding more water change how much peptide is in the vial? No. The total is fixed by what is in the vial. More water lowers the concentration, so each unit holds less and the same quantity occupies more units.

How much water should go into a vial? There is no single correct volume and this page does not recommend one. The choice only changes the concentration, and Chart A shows the result of one, two or three millilitres for each vial size.

What is the difference between U-100 and U-40? The scale the barrel is printed for, and nothing else. The same number of units is a different volume on each, which is why Chart B lists both.

Is this a dose chart? No. It converts between milligrams, millilitres and syringe units. It does not recommend an amount, a frequency or a compound, and for anything you intend to take the person to ask is a licensed healthcare provider.

For anything not on the chart

The charts cover common combinations rather than every one. For any other vial size, water volume or syringe scale, the peptide calculator does the same arithmetic and draws the syringe so you can see where the mark falls.

Chart values here are computed from the two relationships at the top of the page. The U-100 and U-40 definitions, and the consequence of confusing them, come from Merck Animal Health's U-40 guidance.

Sources

This page is educational. It describes what published research reports, not what you should do. Peptides discussed here are largely not approved for human use, and nothing on BioAlmanac is medical advice.

Last updated 25 Oct 2026

Terms used here

Stack
Several separate compounds run at the same time, each in its own vial and on its own schedule.
Peptide
A short chain of amino acids: the same building blocks as a protein, in a chain short enough to behave differently.
Vial
The small sealed glass container a peptide is sold in, holding a stated mass of freeze-dried powder under a rubber stopper.
Dead space
The liquid left in a syringe's hub and needle after the plunger is fully depressed. Small, and it comes out of every dose.
Bacteriostatic water
Sterile water containing a small amount of benzyl alcohol, which stops bacteria multiplying and allows a vial to be used more than once.
Concentration
How much peptide there is in each millilitre of solution, once the vial has been reconstituted.
Unit
A mark printed on an insulin syringe. A unit is not a fixed volume. What it represents depends entirely on the syringe's scale.
Insulin syringe
A small syringe graduated in units rather than millilitres, most commonly with a U-100 scale.